- Research
- Open access
- Published:
The biomechanical study of different fixation techniques for combination fractures of atlas and axis: a finite element analysis
European Journal of Medical Research volume 30, Article number: 184 (2025)
Abstract
Combination atlas–axis fractures are less studied but relatively common with a higher incidence of neurological deficits than isolated C1 or C2 fractures. Several authors focused on the treatment strategies, but there is no study to compare the stability of different fixation methods; neither not yet clear which technique represents the best choice and whether stabilization devices can be efficient and beneficial for complex atlantoaxial fractures. The aim of this study was to compare the biomechanical properties of three fixation techniques: atlantoaxial pedicle screws fixation (PSF), occipital–cervical fusion (OCF) and transarticular screw fixation (TSF) based on combination factures model. Our results showed the range of motion (ROM) of fracture model increased obviously than intact model. The ROM in flexion/extension and rotation of C0–C1 in PSF and TSF models were increased. The ROM of C1–C2 in all conditions in PSF, OCF and TSF models were decreased. The ROM of C2–C3 was decreased in OCF, but remains the same stage in PSF and TSF. These suggested that three surgical methods are effective for the combination fractures of atlas and axis, which can ensure good stability. It can properly increase the ROM of C0–C1 when using PSF. These findings would aid in the treatment of this complex fractures.
Introduction
Combination fractures of atlas and axis account for nearly 3% of cervical spine lesions and 12% of upper cervical spine fractures with a higher incidence of neurological morbidity than isolated C1 and C2 fractures [1,2,3]. The characteristics and treatment strategies are not well known due to the occurrence of the two fractures in combinations often implies a more significant structural and complex mechanical injury. Most patients with combination atlas–axis fractures can be treated successfully with an external immobilization. However, patients who are at high risk for nonunion or non-operative therapy has failed require early surgical, stabilization and fusion. Several authors have focused their reports specifically on combination C1–C2 fractures and their management, but, to the best of our knowledge, no studies have compared the ROM and von Mises stresses of different internal fixations. In this study, we investigated the biomechanical comparison of three surgery techniques: PSF, OCF and TSF, which were performed in combination fractures of atlas and axis based on a finite element model of the intact cervical spine from C0 to C3. The ROM of the cervical, von Mises stress of internal fixation and intervertebral disc were evaluated. Through the study, we can speculate the stability of different surgical methods.
Materials and methods
The intact and fracture model
The model of atlantoaxial complex was developed from the computed tomography (CT) images of a healthy volunteer (24-year-old, male, height 172 cm, weight 70 kg). Ethics committee approval for use of individual participant data was granted by the ethics committee of Shanghai First People’s Hospital prior to this study. Informed consent in the study was also obtained from the participant. The CT images were scanned with a thickness slice of 0.625 mm and were imported into finite element modeling software of Simpleware3.0 (Simpleware Ltd, United Kingdom) to construct a geometrical surface model of atlantoaxial complex. Then, after smoothed by Geomagic 8.0 (Geomagic, Inc. Research Triangle Park, NC, USA), the model was meshed as solid model in Hypermesh 10.0 (Altair engineering, Inc. Executive Park, CA, USA).
The model including vertebral body, disc, facet and major ligaments. Each vertebral body consisted of cortical bone and cancellous bone, and each vertebral disc was composed of nucleus pulposus, annulus fibrosus, and endplates. To simplify the model, 0.5 mm and 6-noded solid elements C3D6 were used for modeling the cortical bone and endplate, 0.5 mm and 4-noded solid elements C3D4 were used for cancellous bone and posterior elements of the vertebrae. The intervertebral discs were composed of nucleus pulposus and annulus fibrosus and modeled based on anatomical data. Major ligaments mimicking the ligamentous structures in the cervical spine were incorporated into the model, including anterior atlanto-occipital membrane (AAOM), Posterior atlanto-occipital membrane (PAOM), apical ligament (AP), alar ligament (AL), tectorial membrane (TM), transversal ligament (TL), anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), ligamentum flavum (LF), joint capsules (JC), cruciated ligaments (CLV), interspinous ligament (ISL), Supraspinous ligament(SSL). Ligament insertion points and area were closely matched with published data [4,5,6]. The detailed values for various materials are tabulated in Table 1 and other ligament properties shown in Table 2, which are the most commonly used values derived from the literature [4, 7, 8]. Cut off the bottom of the odontoid process and cut off the junction between the anterior arch and lateral mass, and the junction between the posterior arch and lateral mass to simulate Jefferson & type II odontoid fracture (Fig. 1). The segmental ROM was also calculated to compare with the intact model.
Fixation models
Three fixation models were established under the condition of Jefferson & type II odontoid fracture by the soft of Rhino4.0 (Robert McNeel & Associates, USA) according to the system sizes and surgery technical specifications. The fixation models are shown in Fig. 2.
Boundary and loading conditions
The inferior endplate of C3 was constrained in all degrees of freedom. A pure moment of 1.5 N·m combined with a pre-compressive load of 50N was applied to C0. Flexion, extension, left/right lateral bending, and left/right axial rotation were simulated.
Validation of the model
The model was loaded in quasi-static loads to validation the rationalities, pure moments (sagittal, transverse and frontal planes) of 1.5 N·m and a compressive load of 50 N were applied to C0 with the C3 firmly fixed. These loading conditions are adopted from the biomechanical experiments and published finite element analysis. The ROM was compared against the in vitro experimental data of Panjabi et al. [9] to assess the validity of the intact model (Fig. 3).
Assessment indexes
The ROM of C0–C3, von Mises stress and stress of the pedicle screws and rods of the three fixation finite element models under six loading conditions(flexion, extension, left/right lateral bending, and left/right axial rotation) were analyzed using the software of Abaqus6.9 (Simulia, USA). No statistical analysis was performed in the manuscript because only one subject was modeled.
Results
Finite element modeling and validation
The intact FE model included 211,371 elements and 66,517 nodes and all the critical components such as discs, facets and major ligaments. There is little difference between the intact model with the previously published models (Fig. 3). Therefore, the model in the present study is effective for further analysis. Figure 4 shows the comparison of the motions of fracture model with intact model under the load-controlled method. Under each loading type, the greatest biomechanical changes occurred in all motions and all segment especially in flexion and extension increased 72.1%, left and right rotation increased 43.8% in C1–C2.
ROM of the fixation models
Compared with the intact model, the ROM in flexion/extension and rotation of C0–C1 was increased over the non-destructive state in PSF of 59.2% and 68.3%, and in TSF of 49.1% and 29.1%. All states of motions of C1–C2 in PSF, OCF and TSF is decreased than the non-destructive state, especially in rotation, and the ROM was the smallest in TSF, followed by PSF and OCF models. The ROM of C2–C3 was decreased than normal in OCF but remain the same stage in PSF and TSF because we choose the segment to fixation in OCF is C3 due to the lateral mass of C1 may not be intact in some cases so that pedicle screw will not be suitable (Fig. 4).
Von Mises stress of the vertebral body and implants
Qualitative investigation of the stress features on fixation devices can predict the tendency of fracture according to the fixation techniques. Under flexion, extension, left–right bending, and left–right rotation conditions. The maximal von Mises stress all occurred in the root of screw and rod in all conditions and all fixation models. The maximal von Mises stress of the PSF is 321.19 MPa in left rotation, 228.84 MPa of the OCF in left bending, 306.71 MPa of the TSF in left rotation (Figs. 5, 6, 7, 8).
Von Mises stress of discs
The values of the largest maximal von Mises stress of the intervertebral disc (C2–C3) in flexion and extension were 5.85 MPa, 1.38 MPa, 5.85Mpa, 3.45 MPa, 0.68 MPa, 3.47Mpa in bending, 3.58 MPa, 0.68 MPa, 3.57 MPa in rotation, in PSF, OCF and TSF, respectively (Figs. 9,10).
Discussion
Actually, any fracture of axis can be accompanied by atlas fracture and vice versa, and once the injuries occur, often implies a complex mechanical injury with more frequently neurological impairment, sometimes fatal [10]. Virtually, it is a challenge to make the treatment of C1–2 instability in which ruptures of the transverse, alar, and apical ligaments [11, 12], dens fractures [13], and odontoidectomies [14] are the common causes of atlantoaxial destabilization that have been studied biomechanically, due to the unique and complex biomechanics of the atlantoaxial. Though several screw-based constructs have been developed for atlantoaxial fixation and the biomechanical properties of these constructs have been assessed in numerous cadaver studies, and several biomechanical studies have compared posterior occipito-atlantoaxial fixation techniques and have generally concluded that the presence of transarticular screws or pedicle screws improves the stability of the construct over provided by other constructs, such as posterior wiring [15, 16]. But combination fractures of atlas and axis is more complicated, the influence on the stability of upper cervical spine is more serious and it is difficult to determine the specific treatment provided to and outcome for most of those patients. Several authors have focused their reports specifically on combination C1–C2 fractures and their management such as atlantoaxial fixation (Gallie, Brooks, Fielding, posterior atlantoaxial pedicle screw fixation, etc.), occipital–cervical fusion and triple anterior screw fixation [1, 2, 17], these techniques have been demonstrated to be safe and effective method for C1–C2 stabilization in most patients, however there is no published finite element analysis study of different fixation techniques; neither not yet clear which technique represents the best choice and whether stabilization devices can be efficient and beneficial for complex atlantoaxial fractures. Therefore, the purpose of this finite element study was to establish a finite element model of Jefferson & type II odontoid fracture based on a validated intact C0–C3 spine model and evaluate the biomechanical properties of different fixation methods (PSF, OCF, TSF) for combination fractures of atlas and axis.
In the current study, we attempted to create a Jefferson & type II odontoid fracture model by cutting off the bottom of the odontoid process and the junction between the anterior arch and lateral mass, posterior arch and lateral mass based on the validated atlantoaxial complex three-dimensional finite element model. The fracture model was built clearly and distinctly, with good geometric similarity. The data generally indicate an increase ROM in all states of motion, especially in flexion/extension increased 72.1%; rotation increased 43.7% of C1–C2, compared with the intact model. For the first time, the loading profiles changes in the upper cervical spine associated with instrumentations have been predicted. Compared with the intact model, three fixation models showed a decrease ROM in all states of motion of C1–C2, the changes of flexion/extension, lateral bending and rotation were 92.2%, 55.7%, 99.0% in PSF; 93.3%, 95.6%, 99.6% in TSF; 89%, 51%, 97.4% in OCF, respectively, and which is consistent with the findings of Li et al. [18]. These predictions certainly seem to suggest that TSF technique in this study contributed most to stability in lateral bending as previously described [19, 20], However, some drawbacks of TSF technique remain: The main disadvantages of C1–C2 transarticular screw fixation are the limitations imposed by the position of the vertebral artery and the acute angle of approach needed for screw place. The PSF method was similarly effective to TSF, both of which were more effective than OCF, one possible reason was we put screws in C2 and C3 rather than C1 and C2 because OCF approach is usually reserved for patients with disruption of the C1 arch and gross C1–C2 instability, in which C1 screw may not be suitable. The result is unexpected that the ROM in all states of motion of C0–C1 was increased in PSF and TSF models, especially in flexion/extension(59.2% of PSF and 49.1% of TSF) and rotation(68.3% in PSF and 29.1% in TSF), potentially predisposing it to accelerated degeneration, while the ROM of C2–C3 remained basically the same. Interestingly, Li reported that C0–C1 or C2–C3 segment may not be more susceptible to degeneration than other nonfixed segments after C1/2 fixation though the ROM of the C0–C1 and C2–C3 segments increased after C1–C2 fixation, This discrepancy may be related to differences in the biomechanical models used or the specific fixation techniques evaluated. On the basis of these findings, the mobile of atlanto-occipital joints may compensatory increase after the fixation of atlantoaxial joints.
The maximal von Mises stress of pedicle screws both happened in rotation among PSF and TSF, but bending in OCF. As showed in the stress distribution results, a maximum level of pedicle screws stress was apparent at the root of the screws under all loading conditions. In clinical practice, the majority of screw breaks occur at this site. Compared with intact model, the stress of intervertebral disc of C2–C3 seemed to be constant at the same level. This result reflects from another aspect, unlike C0–C1, the fixation of C1–C2 had little effect on C2–C3.
An inherent limitation of our study is that it is a finite element analysis, which does not truly reflect clinical application and we only simulate one type of combination fractures and three common fixation methods. Future work may include additional fracture types and fixation techniques, such as anterior methods (Harms plate, TARP, and ATS) and an enhanced posterior Magerl technique with dorsal fixation of the screw base to the axis, to further investigate their biomechanical properties and clinical outcomes. According to the previous finite element analysis studies, all finite element models were reconstructed from single patient’s imagine data and the studies were absent of statistical analysis. Bur we think if we chose more healthy patients, we can build a more standard model and we will keep on with the study.
One of the main advantages of using the finite element method is its time efficiency and computational exactness. From this, it may be possible to identify which aspects of certain fixations are critical to their success and to implement these aspects in current and future designs.
Conclusion
To the authors’ best knowledge, this serves as the first report of application of the finite element method to complex atlantoaxial fractures instrumentations. The data provided by this study demonstrate that all three screw fixation techniques limit motion at the C1 to C2 articulation, provide adequate stability for promotion of fusion. This study indicates that TSF provides superior fixation to the other two. Also, short segment fixation in C1–C2 such as TSF and PSF may affect the stability of C0–C1, but not C2–C3. OCF should be considered as an alternative to PSF and TSF when C1 arch was disruption.
Clinical perspectives
In this work, we established a finite element model of combination fractures of the atlas and axis, and different fixation methods were performed to compare the biomechanical properties.
The finite element study showed that all three fixation techniques can reduce the ROM of C0 to C3 and TSF fixation may offer higher stability to PSF fixation in flexion/extension, lateral bending and rotation in C0–C1.Compared with OCF fixation, short segment fixation in C1–C2 such as TSF and PSF may affect the stability of C0–C1.
This study serves as the first report of application of the finite element method to complex atlantoaxial fractures instrumentations and could provide theoretical reference for the clinical study.
Data availability
No datasets were generated or analysed during the current study.
References
Gleizes V, Jacquot FP, Signoret F, et al. Combined injuries in the upper cervical spine: clinical and epidemiological data over a 14-year period. Eur Spine J. 2000;9(5):386–92.
Dean Q, Jiefu S, Jie W, et al. Minimally invasive technique of triple anterior screw fixation for an acute combination atlas–axis fracture: case report and literature review. Spinal Cord. 2010;48(2):174–7.
Guiot B, Fessler RG. Complex atlantoaxial fractures. J Neurosurg. 1999;91(2 Suppl):139–43.
Yoganandan N, Kumaresan S, Pintar FA. Geometric and mechanical properties of human cervical spine ligaments. J Biomech Eng. 2000;122(6):623–9.
Panjabi MM, Oxland TR, Parks EH. Quantitative anatomy of cervical spine ligaments. Part I. Upper cervical spine. J Spinal Disord. 1991;4(3):270–6.
Brolin K, Halldin P. Development of a finite element model of the upper cervical spine and a parameter study of ligament characteristics. Spine (Phila Pa 1976). 2004;29(4):376–85.
Lee SH, Im YJ, Kim KT, et al. Comparison of cervical spine biomechanics after fixed- and mobile-core artificial disc replacement: a finite element analysis. Spine (Phila Pa 1976). 2011;36(9):700–8.
Yoganandan N, Kumaresan S, Pintar FA. Biomechanics of the cervical spine Part 2. Cervical spine soft tissue responses and biomechanical modeling. Clin Biomech (Bristol, Avon). 2001;16(1):1–27.
Panjabi MM. Cervical spine models for biomechanical research. Spine (Phila Pa 1976). 1998;23(24):2684–700.
Dickman CA, Hadley MN, Browner C, et al. Neurosurgical management of acute atlas–axis combination fractures. A review of 25 cases. J Neurosurg. 1989;70(1):45–9.
Heller JG, Amrani J, Hutton WC. Transverse ligament failure: a biomechanical study. J Spinal Disord. 1993;6(2):162–5.
Panjabi M, Dvorak J, Crisco JJ 3rd, et al. Effects of alar ligament transection on upper cervical spine rotation. J Orthop Res. 1991;9(4):584–93.
Doherty BJ, Heggeness MH, Esses SI. A biomechanical study of odontoid fractures and fracture fixation. Spine (Phila Pa 1976). 1993;18(2):178–84.
Dickman CA, Crawford NR, Brantley AG, et al. Biomechanical effects of transoral odontoidectomy. Neurosurgery. 1995;36(6):1146–52.
Hurlbert RJ, Crawford NR, Choi WG, et al. A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation. J Neurosurg. 1999;90(1 Suppl):84–90.
Oda I, Abumi K, Sell LC, et al. Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques. Spine (Phila Pa 1976). 1999;24(22):2377–82.
Agrillo U, Mastronardi L. Acute combination fracture of atlas and axis: “triple” anterior screw fixation in a 92-year-old man: technical note. Surg Neurol. 2006;65(1):58–62.
Li J, Cao S, Guo D, et al. Biomechanical properties of different anterior and posterior techniques for atlantoaxial fixation: a finite element analysis. J Orthop Surg Res. 2023;18(1):456.
Grob D, Crisco JJ 3rd, Panjabi MM, et al. Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976). 1992;17(5):480–90.
Naderi S, Crawford NR, Song GS, et al. Biomechanical comparison of C1–C2 posterior fixations. Cable, graft, and screw combinations. Spine (Phila Pa 1976). 1998;23(18):1946–55.
Acknowledgements
The author gratefully acknowledges the contributions of Lei Wang and Jia Cao for data collection and Chengcai Jin for dealing with the images.
Funding
The present study was supported by the Program for Tackling Key Problems in Science and Technology in Songjiang District (No. 2024SJKJGG103).
Author information
Authors and Affiliations
Contributions
C.L. and K.H. conceptualized the study and designed the experiments. C.L. performed the experiments and analyzed the data. L.D. contributed to data analysis and interpretation. XG.H. prepared Figures and assisted with experimental procedures. XJ.Z. provided critical feedback and helped shape the research, analysis, and manuscript. C.L. and K.H. and L.D. wrote the main manuscript text. All authors contributed to manuscript revision, read, and approved the submitted version.
Corresponding authors
Ethics declarations
Ethics approval and consent to participate
Ethics committee approval for use of individual participant data was granted by the ethics committee of Shanghai First People’s Hospital prior to this study (No. 2014KY063).
Competing interests
The authors declare no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Liu, C., Huang, K., Dai, L. et al. The biomechanical study of different fixation techniques for combination fractures of atlas and axis: a finite element analysis. Eur J Med Res 30, 184 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s40001-025-02459-w
Received:
Accepted:
Published:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s40001-025-02459-w